Lipped steel studs in a floor track and a head track, the head track a plain track for a loadbearing wall or a slotted deflection head track for an infill wall under a slab, with optional noggings, an outer lining outside and plasterboard inside. Length and height, Floor track, head track and clearance under the slab, Maximum stud spacing, Nogging track, Lining thickness and layers, Finishes
Category: Framed Walls › Panel Walls
By Huu Khanh Nguyen · Updated November 28, 2026
| Name | Default | Unit |
|---|---|---|
| Length | 3000 | mm |
| Thickness | frameY + studDepth + 2 * trackThickness + innerLayers * innerThickness | mm |
| Height | 2700 | mm |
| Maximum Stud Spacing | 600 | mm |
| Stud Web Depth | Math.min(Math.max((92), Math.max(studDocument.options.steelStud.find((row) => row.value == steelStud).depthMin, trackDocument.options.steelTrack.find((row) => row.value == steelTrack).webMin, trackDocument.options.steelTrack.find((row) => row.value == steelTrackChoice).webMin)), Math.min(studDocument.options.steelStud.find((row) => row.value == steelStud).depthMax, trackDocument.options.steelTrack.find((row) => row.value == steelTrack).webMax, trackDocument.options.steelTrack.find((row) => row.value == steelTrackChoice).webMax)) | mm |
| Stud Metal Thickness | Math.min(Math.max((1.15), studDocument.options.steelStud.find((row) => row.value == steelStud).thicknessMin), studDocument.options.steelStud.find((row) => row.value == steelStud).thicknessMax) | mm |
| Track Metal Thickness | Math.min(Math.max((1.15), Math.max(trackDocument.options.steelTrack.find((row) => row.value == steelTrack).thicknessMin, trackDocument.options.steelTrack.find((row) => row.value == steelTrackChoice).thicknessMin)), Math.min(trackDocument.options.steelTrack.find((row) => row.value == steelTrack).thicknessMax, trackDocument.options.steelTrack.find((row) => row.value == steelTrackChoice).thicknessMax)) | mm |
| Clearance Under the Slab | 20 | mm |
| Noggings | noggingDocument.options.steelNogging[1].value | |
| Outer Lining Thickness | 7.5 | mm |
| Outer Lining Layers | 1 | |
| Inside Lining Thickness | 10 | mm |
| Inside Lining Layers | 1 | |
| Steel Finish | ceilingGalvanisedSteel | |
| Outer Lining Finish | ceilingPlasterboard | |
| Inside Lining Finish | ceilingPlasterboard | |
| Frame Offset | outerLayers * outerThickness | mm |
| Bays | Math.ceil(sizeX / studSpacing) | |
| Nogging Rows | sizeZ <= 3000 ? 1 : 2 | |
| Stud Flange Width | (studThickness == studDocument.options.steelStud.find((row) => row.value == steelStud).thickness ? studDocument.options.steelStud.find((row) => row.value == steelStud).width : studDocument.options.steelStud.find((row) => row.value == steelStud).widthElse) | mm |
| Nogging Web | Math.min(Math.max(studDepth, noggingDocument.options.steelNogging.find((row) => row.value == noggingUrl).webMin), noggingDocument.options.steelNogging.find((row) => row.value == noggingUrl).webMax) | mm |
| Nogging Thickness | Math.min(Math.max((studDepth == 150 ? 0.75 : 0.7), noggingDocument.options.steelNogging.find((row) => row.value == noggingUrl).thicknessMin), noggingDocument.options.steelNogging.find((row) => row.value == noggingUrl).thicknessMax) | mm |