Timber Frame Wall With Window Opening

Timber Frame Wall With Window Opening

A timber stud wall, loadbearing or not, with one window opening: trimming studs, a lintel or head trimmer, a sill trimmer, studs above and below and noggings; insulation, sheathing and linings are optional. Opening size, position and sill height, Loadbearing, lintel depth and wall location, Stud section and spacing, Plates and noggings, Sheathing and lining on each side, Insulation and finishes

Details

Category: Framed Walls › Timber Walls

By Huu Khanh Nguyen · Updated November 29, 2026

Parameters

NameDefaultUnit
Length4000mm
Height2400mm
Loadbearingtrue
Opening Width1200mm
Opening Height1200mm
Opening Position1000mm
Sill Height900mm
Wall Locationupper
Lintel Depth190mm
Stud Width90mm
Stud Thickness45mm
Maximum Stud Spacing600mm
Plate Thickness45mm
Top Plate Layers1
Noggingstrue
Maximum Nogging Spacing1350mm
Nogging Section45mm
Sheathing Thickness9.525mm
Sheathing Layers0
Lining Thickness12.5mm
Lining Layers Side One0
Lining Layers Side Two0
Timber FinishtimberSpruceSawn
Sheathing Finishosb
Lining FinishceilingPlasterboard
Frame OffsetlayersSideOne * liningThickness + sheathingLayers * sheathingThicknessmm
Stud TopsizeZ - topPlateLayers * plateThicknessmm
Lintel UndersidesillHeight + openingHeightmm
Header Depthloadbearing ? lintelDepth : sillThicknessmm
Doubling Stud Thicknessloadbearing ? (lintelDepth <= 140 ? 0 : (lintelDepth <= 240 ? 35 : 45)) : 0mm
Lintel Bearingloadbearing ? (lintelSupport > 0 ? lintelSupport : 15) : 0mm
Trimming Assembly ThicknesslintelSupport > 0 && studTop - headHeight >= 400 ? ((!loadbearing || wallLocation == 'upper') ? [[45, 45, 90, 115], [45, 70, 90, 135], [70, 90, 140, 180], [105, 135, 210, 270]][(openingWidth > 1800 ? 1 : 0) + (openingWidth > 3000 ? 1 : 0) + (openingWidth > 3600 ? 1 : 0)][[35, 45, 70, 90].indexOf(studThickness)] : [[45, 70, 90, 135], [70, 70, 115, 135], [70, 90, 140, 180]][(openingWidth > 900 ? 1 : 0) + (openingWidth > 1800 ? 1 : 0)][[35, 45, 70, 90].indexOf(studThickness)]) + lintelSupport : (!loadbearing || wallLocation == 'upper') ? [[45, 45, 90, 115], [45, 70, 90, 135], [70, 90, 140, 180], [105, 135, 210, 270]][(openingWidth > 1800 ? 1 : 0) + (openingWidth > 3000 ? 1 : 0) + (openingWidth > 3600 ? 1 : 0)][[35, 45, 70, 90].indexOf(studThickness)] : [[45, 70, 90, 135], [70, 70, 115, 135], [70, 90, 140, 180]][(openingWidth > 900 ? 1 : 0) + (openingWidth > 1800 ? 1 : 0)][[35, 45, 70, 90].indexOf(studThickness)]mm
Left Run EndopeningX - trimmingWidthmm
Bays LeftMath.ceil(runLeft / studSpacing)
Pitch LeftrunLeft / bayCountLeftmm
Right Run LengthsizeX - openingX - openingWidth - trimmingWidthmm
Bays RightMath.ceil(runRight / studSpacing)
Pitch RightrunRight / bayCountRightmm
Bays Across the OpeningMath.ceil(openingWidth / studSpacing)
Pitch Across the OpeningopeningWidth / spanBaysmm
Sill Trimmer ThicknessopeningWidth <= 2000 ? 35 : (openingWidth <= 2400 ? 45 : (openingWidth <= 3000 ? 90 : 135))mm
Nogging Rowsnogged ? Math.ceil((sizeZ - (1 + topPlateLayers) * plateThickness) / noggingSpacing) - 1 : 0
Insulationfalse